← Full COPV catalog
CatalogIndustrial gas › DRX-090-187Deutsche Version →

DRX-090-187 — 9 L industrial gas composite cylinder, 300 bar

πCE

In stock — order

The DRX-090-187 is a 9 L Type IV composite cylinder rated at 300 bar (4500 psi) for breathing air, nitrogen and industrial gas service. Carbon-fibre full-composite construction, 5 kg — a fraction of the weight of the equivalent steel cylinder.

Part No.VolumePressureØ DiaLengthWeightH₂ / Grav.ApprovalsLifespan
DRX-090-187 9 L549 cu in 300 bar4,500 psi 187 mm7.36 in 497 mm19.57 in 5.00 kg11.02 lb πCE 15 yr
Safety factor WP = burst ÷ SF · derived ratings are not certified
497 mmØ 187 mm
300 bar · 4,500 psi
Part numberDRX-090-187
MetricImperial
Working pressure300 bar4,500 psi
Burst pressure (3 × WP)900 bar13,500 psi
Water volume9 L549 cu in
DiameterØ 187 mmØ 7.36 in
Length497 mm19.57 in
Weight5.00 kg11.02 lb
Temperature range−40 to +60 °C−40 to +140 °F
ThreadsM18×1.5 · 17E · 25E · 3/4″-16 UNF · 5/8″-18 UNF · M12×1 · others on request
QualificationEN 12245
Service life15 yr
Request quote

We email the DRX-090-187 datasheet within 1 working day. No lists, no spam.

R&D configurations — reduced safety factor

Catalog ratings use a burst safety factor of 3.0 (burst = 3 × working pressure). For R&D, space and qualification-by-project programs, the same structure can be operated at a customer-selected safety factor: the burst pressure of 900 bar is fixed by the structure, and the working pressure is derived as WP = burst ÷ SF. Derived ratings are engineering references — CE/π certification applies at SF 3.0 only.

Safety factorPart numberWorking pressure (metric)Working pressure (imperial)Rating
SF 3.0 DRX-090-187 300 bar 4,500 psi Catalog — certified rating
SF 2.50 DRX-090-187-SF2.5 360 bar 5,400 psi Engineering configuration — not certified
SF 2.25 DRX-090-187-SF2.25 400 bar 6,000 psi Engineering configuration — not certified
SF 2.0 DRX-090-187-SF2 450 bar 6,750 psi Engineering configuration — not certified

Click a configuration to select it — the drawing caption, specification and the request buttons above will reference that exact configuration.

Any factor from 1.5 to 10 can be configured in the catalog R&D view — quotes carry the -SF suffix automatically.

Related industrial gas cylinders

Frequently asked questions

What gases can the DRX-090-187 be used with?
Breathing air, nitrogen and other industrial gases — specify the gas medium when ordering.
How much lighter is the DRX-090-187 than a steel cylinder?
At 5 kg the DRX-090-187 weighs roughly a third of an equivalent steel cylinder of the same water capacity.
What is the service life of the DRX-090-187?
15 yr, tested per EN 12245.
Can the DRX-090-187 be ordered at a lower safety factor than 3.0?
Yes. Catalog ratings use a burst safety factor of 3.0; for R&D and qualification-by-project programs the same structure is quoted at customer-selected safety factors (e.g. SF 2.5, SF 2.25, SF 2.0) with the working pressure derived as burst ÷ SF — ordered as DRX-090-187-SF2.5 and so on. Derived ratings are engineering configurations, not certified ratings.