In stock — order
The DRX-0075-122 is a 0.75 L Type IV composite cylinder rated at 440 bar (6400 psi) for breathing air, nitrogen and industrial gas service. Carbon-fibre full-composite construction, 0.54 kg — a fraction of the weight of the equivalent steel cylinder.
| Part No. | Volume | Pressure | Ø Dia | Length | Weight | H₂ / Grav. | Approvals | Lifespan |
|---|---|---|---|---|---|---|---|---|
| DRX-0075-122 | 0.75 L46 cu in | 440 bar6,400 psi | 122 mm4.8 in | 140 mm5.51 in | 0.54 kg1.19 lb | — | — |
| Part number | DRX-0075-122 | |
|---|---|---|
| Metric | Imperial | |
| Working pressure | 440 bar | 6,400 psi |
| Burst pressure (3 × WP) | 1320 bar | 19,200 psi |
| Water volume | 0.75 L | 46 cu in |
| Diameter | Ø 122 mm | Ø 4.8 in |
| Length | 140 mm | 5.51 in |
| Weight | 0.54 kg | 1.19 lb |
| Temperature range | −40 to +60 °C | −40 to +140 °F |
| Threads | M18×1.5 · 17E · 25E · 3/4″-16 UNF · 5/8″-18 UNF · M12×1 · others on request | |
| Qualification | Manufacturer specification | |
| Service life | — | |
We email the DRX-0075-122 datasheet within 1 working day. No lists, no spam.
Catalog ratings use a burst safety factor of 3.0 (burst = 3 × working pressure). For R&D, space and qualification-by-project programs, the same structure can be operated at a customer-selected safety factor: the burst pressure of 1320 bar is fixed by the structure, and the working pressure is derived as WP = burst ÷ SF. Derived ratings are engineering references — CE/π certification applies at SF 3.0 only.
| Safety factor | Part number | Working pressure (metric) | Working pressure (imperial) | Rating | |
| SF 3.0 | DRX-0075-122 | 440 bar | 6,400 psi | Catalog — certified rating | |
| SF 2.50 | DRX-0075-122-SF2.5 | 528 bar | 7,700 psi | Engineering configuration — not certified | |
| SF 2.25 | DRX-0075-122-SF2.25 | 586.7 bar | 8,550 psi | Engineering configuration — not certified | |
| SF 2.0 | DRX-0075-122-SF2 | 660 bar | 9,600 psi | Engineering configuration — not certified |
Click a configuration to select it — the drawing caption, specification and the request buttons above will reference that exact configuration.
Any factor from 1.5 to 10 can be configured in the catalog R&D view — quotes carry the -SF suffix automatically.
DRX-008-100DRX-008-111HDRX-005DRX-010-88