In stock — order
The DRX-050-136 is a 5 L Type IV composite cylinder rated at 200 bar (3000 psi) for breathing air, nitrogen and industrial gas service. Carbon-fibre full-composite construction, 2.85 kg — a fraction of the weight of the equivalent steel cylinder.
| Part No. | Volume | Pressure | Ø Dia | Length | Weight | H₂ / Grav. | Approvals | Lifespan |
|---|---|---|---|---|---|---|---|---|
| DRX-050-136 | 5 L305 cu in | 200 bar3,000 psi | 136 mm5.35 in | 510 mm20.08 in | 2.85 kg6.28 lb | — | π | NLL |
| Part number | DRX-050-136 | |
|---|---|---|
| Metric | Imperial | |
| Working pressure | 200 bar | 3,000 psi |
| Burst pressure (3 × WP) | 600 bar | 9,000 psi |
| Water volume | 5 L | 305 cu in |
| Diameter | Ø 136 mm | Ø 5.35 in |
| Length | 510 mm | 20.08 in |
| Weight | 2.85 kg | 6.28 lb |
| Temperature range | −40 to +60 °C | −40 to +140 °F |
| Threads | M18×1.5 · 17E · 25E · 3/4″-16 UNF · 5/8″-18 UNF · M12×1 · others on request | |
| Qualification | EN 12245 | |
| Service life | No Limited Lifespan (periodic testing) | |
We email the DRX-050-136 datasheet within 1 working day. No lists, no spam.
Catalog ratings use a burst safety factor of 3.0 (burst = 3 × working pressure). For R&D, space and qualification-by-project programs, the same structure can be operated at a customer-selected safety factor: the burst pressure of 600 bar is fixed by the structure, and the working pressure is derived as WP = burst ÷ SF. Derived ratings are engineering references — CE/π certification applies at SF 3.0 only.
| Safety factor | Part number | Working pressure (metric) | Working pressure (imperial) | Rating | |
| SF 3.0 | DRX-050-136 | 200 bar | 3,000 psi | Catalog — certified rating | |
| SF 2.50 | DRX-050-136-SF2.5 | 240 bar | 3,600 psi | Engineering configuration — not certified | |
| SF 2.25 | DRX-050-136-SF2.25 | 266.7 bar | 4,000 psi | Engineering configuration — not certified | |
| SF 2.0 | DRX-050-136-SF2 | 300 bar | 4,500 psi | Engineering configuration — not certified |
Click a configuration to select it — the drawing caption, specification and the request buttons above will reference that exact configuration.
Any factor from 1.5 to 10 can be configured in the catalog R&D view — quotes carry the -SF suffix automatically.
DRX-050-182HDRX-043DRX-040-114DRX-040-122