DRX-050-182 — 5 L industrial gas composite cylinder, 210 bar

In stock — order

The DRX-050-182 is a 5 L Type IV composite cylinder rated at 210 bar (3050 psi) for breathing air, nitrogen and industrial gas service. Carbon-fibre full-composite construction, 2.5 kg — a fraction of the weight of the equivalent steel cylinder.

Part No.VolumePressureØ DiaLengthWeightH₂ / Grav.ApprovalsLifespan
DRX-050-182 5 L305 cu in 210 bar3,050 psi 182 mm7.17 in 348 mm13.7 in 2.50 kg5.51 lb 10 yr
Safety factor WP = burst ÷ SF · derived ratings are not certified
348 mmØ 182 mm
210 bar · 3,050 psi
Part numberDRX-050-182
MetricImperial
Working pressure210 bar3,050 psi
Burst pressure (3 × WP)630 bar9,150 psi
Water volume5 L305 cu in
DiameterØ 182 mmØ 7.17 in
Length348 mm13.7 in
Weight2.50 kg5.51 lb
Temperature range−40 to +60 °C−40 to +140 °F
ThreadsM18×1.5 · 17E · 25E · 3/4″-16 UNF · 5/8″-18 UNF · M12×1 · others on request
QualificationManufacturer specification
Service life10 yr
Request quote

We email the DRX-050-182 datasheet within 1 working day. No lists, no spam.

R&D configurations — reduced safety factor

Catalog ratings use a burst safety factor of 3.0 (burst = 3 × working pressure). For R&D, space and qualification-by-project programs, the same structure can be operated at a customer-selected safety factor: the burst pressure of 630 bar is fixed by the structure, and the working pressure is derived as WP = burst ÷ SF. Derived ratings are engineering references — CE/π certification applies at SF 3.0 only.

Safety factorPart numberWorking pressure (metric)Working pressure (imperial)Rating
SF 3.0 DRX-050-182 210 bar 3,050 psi Catalog — certified rating
SF 2.50 DRX-050-182-SF2.5 252 bar 3,650 psi Engineering configuration — not certified
SF 2.25 DRX-050-182-SF2.25 280 bar 4,050 psi Engineering configuration — not certified
SF 2.0 DRX-050-182-SF2 315 bar 4,600 psi Engineering configuration — not certified

Click a configuration to select it — the drawing caption, specification and the request buttons above will reference that exact configuration.

Any factor from 1.5 to 10 can be configured in the catalog R&D view — quotes carry the -SF suffix automatically.

Other configurations of the DRX-050

Related industrial gas cylinders

Frequently asked questions

What gases can the DRX-050-182 be used with?
Breathing air, nitrogen and other industrial gases — specify the gas medium when ordering.
How much lighter is the DRX-050-182 than a steel cylinder?
At 2.5 kg the DRX-050-182 weighs roughly a third of an equivalent steel cylinder of the same water capacity.
What is the service life of the DRX-050-182?
10 yr, tested per Manufacturer specification.
Can the DRX-050-182 be ordered at a lower safety factor than 3.0?
Yes. Catalog ratings use a burst safety factor of 3.0; for R&D and qualification-by-project programs the same structure is quoted at customer-selected safety factors (e.g. SF 2.5, SF 2.25, SF 2.0) with the working pressure derived as burst ÷ SF — ordered as DRX-050-182-SF2.5 and so on. Derived ratings are engineering configurations, not certified ratings.