Pre-orders open — development in final phase
The HDRX-068-HE is a 6.8 L Type IV composite helium cylinder rated at 350 bar (5000 psi) built on the MEYER sealed liner — no measurable helium permeation, verified by helium leak detection. Helium is the industry's most escape-prone gas; the sealed liner keeps it stored in a full-composite cylinder of just 2.8 kg, for satellite pressurant systems, tracer-gas rigs, lighter-than-air platforms and research.
| Part No. | Volume | Pressure | Ø Dia | Length | Weight | H₂ / Grav. | Approvals | Lifespan |
|---|---|---|---|---|---|---|---|---|
| HDRX-068-HE | 6.8 L415 cu in | 350 bar5,000 psi | 158 mm6.22 in | 526 mm20.71 in | 2.80 kg6.17 lb | — | πCEISOHEDEVPRE-ORDER | 20 yr |
| Part number | HDRX-068-HE | |
|---|---|---|
| Metric | Imperial | |
| Working pressure | 350 bar | 5,000 psi |
| Burst pressure (3 × WP) | 1050 bar | 15,000 psi |
| Water volume | 6.8 L | 415 cu in |
| Diameter | Ø 158 mm | Ø 6.22 in |
| Length | 526 mm | 20.71 in |
| Weight | 2.80 kg | 6.17 lb |
| Temperature range | −40 to +60 °C | −40 to +140 °F |
| Threads | M18×1.5 · 17E · 25E · 3/4″-16 UNF · 5/8″-18 UNF · M12×1 · others on request | |
| Qualification | EN 12245:2022 (He service) | |
| Service life | 20 yr | |
We email the HDRX-068-HE datasheet within 1 working day. No lists, no spam.
Catalog ratings use a burst safety factor of 3.0 (burst = 3 × working pressure). For R&D, space and qualification-by-project programs, the same structure can be operated at a customer-selected safety factor: the burst pressure of 1050 bar is fixed by the structure, and the working pressure is derived as WP = burst ÷ SF. Derived ratings are engineering references — CE/π certification applies at SF 3.0 only.
| Safety factor | Part number | Working pressure (metric) | Working pressure (imperial) | Rating | |
| SF 3.0 | HDRX-068-HE | 350 bar | 5,000 psi | Catalog — certified rating | |
| SF 2.50 | HDRX-068-HE-SF2.5 | 420 bar | 6,000 psi | Engineering configuration — not certified | |
| SF 2.25 | HDRX-068-HE-SF2.25 | 466.7 bar | 6,650 psi | Engineering configuration — not certified | |
| SF 2.0 | HDRX-068-HE-SF2 | 525 bar | 7,500 psi | Engineering configuration — not certified |
Click a configuration to select it — the drawing caption, specification and the request buttons above will reference that exact configuration.
Any factor from 1.5 to 10 can be configured in the catalog R&D view — quotes carry the -SF suffix automatically.
HDRX-068-H2HDRX-068-H2-ULHDRX-068-HE-ULHDRX-068HDRX-068-MIL
HDRX-068-HE-ULHDRX-090-HEHDRX-043-HEHDRX-030-HE